BRK Codes and Standards
EXCERPTS FROM CODES AND STANDARDS
For your convenience we have posted excerpts from some of the most widely used standards and national electrical & building codes referencing smoke and carbon monoxide alarms. Please note that these are only excerpts, and you must consult all local and national building codes and AHJ's (Authority having Jurisdiction) before beginning any installations.
AGENCY PLACEMENT RECOMMENDATIONS
Standards: ANSI/UL 217 Single and Multiple Station Smoke Alarms.
NFPA 72 (National Fire Code) Chapter 11
For your information, the National Fire Protection Association's Standard 72, reads as follows:
11.5.1 One- and Two-Family Dwelling Units.
11.5.1.1 Smoke Detection. Where required by applicable laws, codes, or standards for the specified occupancy, approved single-station and multiple-station Smoke Alarms shall be installed as follows: (1) In all sleeping rooms Exception: Smoke Alarms shall not be required in sleeping rooms in existing one- and two-family dwelling units. (2) Outside of each separate sleeping area, in immediate vicinity of the sleeping rooms. (3) On each level of the dwelling unit, including basements Exception: In existing one- and two family dwelling units, approved Smoke Alarms powered by batteries are permitted.
A.11.8.3 Are More Smoke Alarms Desirable?
The required number of Smoke Alarms might not provide reliable early warning protection for those areas separated by a door from the areas protected by the required Smoke Alarms. For this reason, it is recommended that the householder consider the use of additional Smoke Alarms for those areas for increased protection. The additional areas include the basement, bedrooms, dining room, furnace room, utility room, and hallways not protected by the required Smoke Alarms. The installation of Smoke Alarms in kitchens, unfinished attics, or garages is not normally recommended, as these locations occasionally experience conditions that can result in improper operation.
NFPA 101 (Life Safety Code) 2003 Excerpt from pages 101–80 to 81; 101-209
9.6.2.10 Smoke Alarms.
9.6.2.10.1 Where required by another section of this Code, single-station and multiple-station smoke alarms shall be in accordance with NFPA 72®, National Fire Alarm Code®. System smoke detectors in accordance with NFPA 72®, National Fire Alarm Code®, and arranged to function in the same manner as single-station or multiple-station smoke alarms shall be permitted in lieu of smoke alarms.
9.6.2.10.2 Smoke alarms, other than battery-operated devices as permitted by other sections of this Code, or battery-operated devices complying with 9.6.1.3 and the low-power wireless system requirements of NFPA72®, National Fire Alarm Code®, shall receive their operating power from the building electrical system.
9.6.2.10.3* In new construction, where two or more smoke alarms are required within a dwelling unit, suite of rooms, or similar area, they shall be arranged so that operation of any smoke alarm shall cause the alarm in all smoke alarms within the dwelling unit, suite of rooms, or similar area to sound, unless otherwise permitted by the following:
(1) The requirement of 9.6.2.10.3 shall not apply where permitted by another section of this Code.
(2) The requirement of 9.6.2.10.3 shall not apply to configurations that provide equivalent distribution of the alarm signal.
9.6.2.10.4 The alarms shall sound only within an individual dwelling unit, suite of rooms, or similar area and shall not actuate the building fire alarm system, unless otherwise permitted by the authority having jurisdiction. Remote annunciation shall be permitted.
24.3.4 Detection, Alarm, and Communications Systems.
Smoke alarms or a smoke detection system shall be provided in accordance with either 24.3.4.1 or 24.3.4.2, as modified by 24.3.4.3.
24.3.4.1 Smoke alarms shall be installed in accordance with 9.6.2.10 in the following locations:
(1) All sleeping rooms in other than existing one- and two family dwellings
(2) Outside of each separate sleeping area, in the immediate vicinity of the sleeping rooms
(3) On each level of the dwelling unit, including basements
24.3.4.2 Dwelling units shall be protected by an approved smoke detection system in accordance with Section 9.6 and equipped with an approved means of occupant notification.
24.3.4.3 In existing one- and two-family dwellings, approved smoke alarms powered by batteries shall be permitted.
California State Fire Marshal (CSFM)
Early warning detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows: A Smoke Alarm installed in each separate sleeping area (in the vicinity, but outside bedrooms), and Heat or Smoke Alarms in the living rooms, dining rooms, bedrooms, kitchens, hallways, finished attics, furnace rooms, closets, utility and storage rooms, basements, and attached garages.
REGULATORY INFORMATION FOR CO ALARMS
WHAT LEVELS OF CO CAUSE AN ALARM?
Underwriters Laboratories Inc. Standard UL2034 requires residential CO Alarms to sound when exposed to levels of CO and exposure times as described below. They are measured in parts per million (ppm) of CO over time (in minutes). UL2034 Required Alarm Points*:
- If the alarm is exposed to 400 ppm of CO, IT MUST ALARM BETWEEN 4 and 15 MINUTES.
- If the alarm is exposed to 150 ppm of CO, IT MUST ALARM BETWEEN 10 and 50 MINUTES.
- If the alarm is exposed to 70 ppm of CO, IT MUST ALARM BETWEEN 60 and 240 MINUTES. * Approximately 10% COHb exposure at levels of 10% to 95% Relative Humidity (RH). The unit is designed not to alarm when exposed to a constant level of 30 ppm for 30 days. CO Alarms are designed to alarm before there is an immediate life threat. Since you cannot see or smell CO, never assume it’s not present.
- An exposure to 100 ppm of CO for 20 minutes may not affect average, healthy adults, but after 4 hours the same level may cause headaches.
- An exposure to 400 ppm of CO may cause headaches in average, healthy adults after 35 minutes, but can cause death after 2 hours.
Gas Detection at Typical Temperature and Humidity Ranges: The CO Alarm is not formulated to detect CO levels below 30 ppm typically. UL tested for false alarm resistance to Methane (500 ppm), Butane (300 ppm), Heptane (500 ppm), Ethyl Acetate (200 ppm), Isopropyl Alcohol (200 ppm) and Carbon Dioxide (5000 ppm). Values measure gas and vapor concentrations in parts per million.
Audible Alarm: 85 dB minimum at 10 feet (3 meters).
REGULATORY INFORMATION FOR SMOKE ALARMS RECOMMENDED LOCATIONS FOR SMOKE ALARMS
Installing Smoke Alarms in Single-Family Residences
The National Fire Protection Association (NFPA), recommends one Smoke Alarm on every floor, in every sleeping area, and in every bedroom. In new construction, the Smoke Alarms must be AC powered and interconnected. See “Agency Placement Recommendations” for details. For additional coverage, it is recommended that you install a Smoke Alarm in all rooms, halls, storage areas, finished attics, and basements, where temperatures normally remain between 40° F (4° C) and 100° F (38° C). Make sure no door or other obstruction could keep smoke from reaching the Smoke Alarms. More specifically, install Smoke Alarms:
- On every level of your home, including finished attics and basements.
- Inside every bedroom, especially if people sleep with the door partly or completely closed.
- In the hall near every sleeping area. If your home has multiple sleeping areas, install a unit in each. If a hall is more than 40 feet long (12 meters), install a unit at each end.
- At the top of the first-to-second floor stairway, and at the bottom of the basement stairway.
IMPORTANT! Specific requirements for Smoke Alarm installation vary from state to state and from region to region. Check with your local Fire Department for current requirements in your area. It is recommended AC or AC/DC units be interconnected for added protection.
INSTALLING SMOKE ALARMS IN MOBILE HOMES
For minimum security install one Smoke Alarm as close to each sleeping area as possible. For more security, put one unit in each room. Many older mobile homes (especially those built before 1978) have little or no insulation. If your mobile home is not well insulated, or if you are unsure of the amount of insulation, it is important to install units on inside walls only. Smoke Alarms should be installed where temperatures normally remain between 40° F (4° C) and 100° F (38° C).
STATE LISTING CARDS FOR BRK/FIRST ALERT PRODUCTS
California State Fire Marshal
CSFM-100S
CSFM-7010/7020 Series
CSFM-9120 Series
CSFM-FG250 Series
CSFM-HD6135F
CSFM-HD6135FB
OneLink
CSFM-RM4
CSFM-SA340
CSFM-SA710/SA720 Series
CSFM-SCO1
CSFM-SCO5/SCO7 Series
CSFM-SC7010B/SC7010BV Series
CSFM-SC9120B
Maryland State Fire Marshal
MSFM-7010/7020 Series
MSFM-9120 Series
MSFM-FG250 Series
OneLink
MSFM-SCO5/SCO7 Series
MSFM-SC7010B/SC7010BV
MSFM-SC9120B
MSFM-SL177
IMPORTANT RELATED LINKS
www.intlcode.org
International Code Council. The ICC founders - the Building Officials and Code Administrators (BOCA), the International Conference of Building Officials (ICBO), and the Southern Building Code Congress International (SBCCI) - created the ICC in response to technical disparities among the three sets of model codes now in use in the U.S.A.
www.nfpa.org
NFPA International
www.fema.gov
FEMA (Federal Emergency Management Agency)
www.iafc.org
International Association of Fire Chiefs. Established in 1873, the International Association of Fire Chiefs represents the leadership of over 1.2 million firefighters. IAFC members are the world's leading experts in firefighting, emergency medical services, terrorism response, hazardous materials spills, natural disasters, search and rescue, and public safety legislation.
www.osha.gov
Occupational Safety Health Administration (OSHA)
www.hud.gov
HUD- US department of Housing & Urban Development
www.usfa.fema.gov
USFA - US Fire Marshall Administration
www.fire.ca.gov
CSFM - California State Fire Marshall
www.oregon.gov/OSP/SFM/
Oregon State Fire Marshall
http://www.fire-marshal.ri.gov/
Rhode Island Fire Marshal’s Web Site
http://www.fsc.ri.gov/
Rhode Island Fire Safety Code Web Site
https://www.mass.gov/orgs/department-of-fire-services
Massachusetts State Fire Marshal
https://www1.nyc.gov/site/buildings/codes/mea-index.page
MEA - New York City Building Code
https://mdsp.maryland.gov/firemarshal/Pages/StateFireMarshal.aspx
Maryland State Fire Marshal